<ErrorNumber>22022</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Plate (%lu mm) larger than expected  (%lu mm), remove from load table or correct the size
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>ThermoFlex</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check the table plate sensor and ensure it is working correctly and plugged in.
Another cause could be kinks in the media.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Remove plate from recorder and then resume production with the proper size plate.
</text></DescriptionText>
</OperatorAction>
<Cause>
While winding the plate onto the drum, either the plate exceeds the maximum plate
size allowed or the plate still covers the sensor after the drum stops moving.
</Cause>